No "Connected SafeLOGIC modules" could be defined if a combination of Automation Studio 4.3.4 (or higher), Safety Release 1.10 and Automatin Runtime < A4.33 was used.Integrated engineering for PLCs, safety, motion, drives, SCADA and control panels
Automation studio 5.0 library download update#
Update of the HWX entry "IOImage" for special targets. Logger number 102661 occoured upon multiple readingof several diagnostic values.Īdditional diagnostic values (PLK objects 0x2410 / 44.
![automation studio 5.0 library download automation studio 5.0 library download](https://millionheadpro.com/image/product/1597301502_4.jpg)
Logger number 102661 "NoTX-buffer available" Logger entry 122913 could happen sporadically with large projects. calculation of Safety response time has been updated.ĭata sheet: Default Additional Tolerated Packet LossĬorrection of permitted values in the data sheet.įirmware: 5\57991_1.fw(314), 6\57991_1.fw(331)įixed problems with reACTION modules at X20(c)SL8101. See chapture "Version history" in the data sheet.
![automation studio 5.0 library download automation studio 5.0 library download](https://webintopc.com/wp-content/uploads/2021/06/Automation-Studio-k0B0.jpg)
Parameter "Process Data Transmission Rate" added.Įnhace documentation for the case that SafeLOGIC is stuck in NoExecution state.
Automation studio 5.0 library download code#
Incorrect lengthcheck when enabling POWERLINK mapping of additional node number (abort code 0圆040042, logger message 30287).ĭata sheet: parameter "Process Data Transmission Rate" This could lead to an increased safety response time. The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
Automation studio 5.0 library download full#
SafeLOGIC cycle time parameter must be a full multiple of the POWERLINK cycle time. Triple memory for safe input data to 6kB. Removed misleading value for maximum "Application memory" from technical data.Īdded new diagnostic values to channel list.ĭouble flag memory and flag counter to 256kB respectively 16384 flags. Support larger project files (logger message 100361 "Notenough memory for file data").
Max number of SL<->CPU channels has been increased.Major (even incompatible) changes for mapp SafetyĪTTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Support SafeDOMAIN-to-SafeDOMAIN communication To disable setup mode via confirmation button, the confirmation button has to be pressed for 20 seconds
Max number of SL<->CPU channels has been increased (requires mappSafety >=5.7 and AR >= A4.72).ĭisable setup mode via confirmation buttonSafeDESIGNER does not show more than 10 SafeDOMAIN to SafeDOMAINconnection,even if more are configured in Automation Studio. SafeDESIGNER does not show more than 10 SafeDOMAIN to SafeDOMAIN connections Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Support for automatic DNA configuration from AS 4.9.1 Using high SafeNode IDs with gaps lead to error -1073561597 See the datasheet for detailed descriptionĮrror by using high SafeNode IDs with gaps Parameter "Maximum number of simultaneous module startups" added. Possibility to parametrize the maximum number of simultaneous module startups Optimization of the internal communication timing between uPC and uPS Optimization of theinternal communication between uPC and uPS The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-13987) The data for the power calculation of the data sheet is included in the HWX. The power calculation of the modules is supported NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Corrected width of X20SL8110 in technical data